SCHNEIDER ELECTRIC GV2L22
SCHNEIDER ELECTRIC GV2L22
€ 22,93 Excl. tax: € 18,95
3 in stock
3 in stock
- Pick up from our store
Netherlands, Europe
Today
- Standard delivery
- Express delivery
Delivery:
Payment Methods:
Description
Motor circuit breaker, TeSys GV2, 3P, 25 A, magnetic, rotary handle, screw clamp terminals: Specifications, Main, Range, TeSys Deca, Product name, TeSys GV2, TeSys Deca, Product or component type, Motor circuit breaker, Device short name, GV2L, Device application, Motor protection, Trip unit technology, Magnetic, Complementary, Poles description, 3P, Network type, AC, Utilisation category, Category A conforming to IEC 60947-2, AC-3 conforming to IEC 60947-4-1, AC-3e conforming to IEC 60947-4-1, Network frequency, 50/60 Hz conforming to IEC 60947-2, Fixing mode, 35 mm symmetrical DIN rail: clipped, Panel: screwed (with 2 x M4 screws), Motor power kW, 9 kW at 400/415 V AC 50/60 Hz, 11 kW at 400/415 V AC 50/60 Hz, 11 kW at 500 V AC 50/60 Hz, 15 kW at 500 V AC 50/60 Hz, 18.5 kW at 690 V AC 50/60 Hz, Breaking capacity, 50 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2, [Ics] rated service short-circuit breaking capacity, 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2, control type, Rotary handle, [In] rated current, 25 A, Magnetic tripping current, 327 A, [Ith] conventional free air thermal current, 25 A conforming to IEC 60947-4-1, [Ue] rated operational voltage, 690 V AC 50/60 Hz conforming to IEC 60947-2, [Ui] rated insulation voltage, 690 V AC 50/60 Hz conforming to IEC 60947-2, [Uimp] rated impulse withstand voltage, 6 kV conforming to IEC 60947-2, Suitability for isolation, Yes conforming to IEC 60947-1 § 7-1-6, Power dissipation per pole, 1.8 W, Mechanical durability, 100000 cycles, Electrical durability, 100000 cycles for AC-3 at 415 V In, 100000 cycles for AC-3e at 415 V In, Rated duty, Continuous conforming to IEC 60947-4-1, Tightening torque, 1.7 N.m – on screw clamp terminal, Width, 45 mm, height, 89 mm, Depth, 97 mm, Net weight, 0.33 kg, Colour, Dark grey, Environment, Standards, EN/IEC 60947-2, UL 60947-4-1, CSA C22.2 No 60947-4-1, product certifications, CCC, UL, CSA, EAC, LROS (Lloyds register of shipping), BV, RINA, DNV-GL, UKCA, IECEE CB Scheme, IK degree of protection, IK04, IP degree of protection, IP20 conforming to IEC 60529, Climatic withstand, Conforming to IACS E10, Ambient air temperature for storage, -40…80 °C, Fire resistance, 960 °C conforming to IEC 60695-2-11, Ambient air temperature for operation, -20…60 °C, Mechanical robustness, Shocks: 30 Gn for 11 ms, Vibrations: 5 Gn, 5…150 Hz, Operating altitude, 2000 m Main: Range: TeSys Deca Product name: TeSys GV2 Product or component type: Motor circuit breaker Device short name: GV2L Device application: Motor protection Specifications: TeSys Deca: TeSys GV2 Product or component type: Motor circuit breaker Device short name: GV2L Device application: Motor protection Trip unit technology: Magnetic Poles description: 3P Network type: AC Utilisation category: Category A conforming to IEC 60947-2, AC-3 conforming to IEC 60947-4-1, AC-3e conforming to IEC 60947-4-1 Network frequency: 50/60 Hz conforming to IEC 60947-2 Fixing mode: 35 mm symmetrical DIN rail: clipped, Panel: screwed (with 2 x M4 screws) Motor power kW: 9 kW at 400/415 V AC 50/60 Hz, 11 kW at 400/415 V AC 50/60 Hz, 11 kW at 500 V AC 50/60 Hz, 15 kW at 500 V AC 50/60 Hz, 18.5 kW at 690 V AC 50/60 Hz Breaking capacity: 50 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 Control type: Rotary handle [In] rated current: 25 A Magnetic tripping current: 327 A [Ith] conventional free air thermal current: 25 A conforming to IEC 60947-4-1 [Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2 Suitability for isolation: Yes conforming to IEC 60947-1 § 7-1-6 Power dissipation per pole: 1.8 W Mechanical durability: 100000 cycles Electrical durability: 100000 cycles for AC-3 at 415 V In, 100000 cycles for AC-3e at 415 V In Rated duty: Continuous conforming to IEC 60947-4-1 Tightening torque: 1.7 N.m – on screw clamp terminal Width: 45 mm Height: 89 mm Depth: 97 mm Net weight: 0.33 kg Colour: Dark grey Environment: Standards Standards: EN/IEC 60947-2, UL 60947-4-1, CSA C22.2 No 60947-4-1 Product certifications: CCC, UL, CSA, EAC, LROS (Lloyds register of shipping), BV, RINA, DNV-GL, UKCA, IECEE CB Scheme IK degree of protection: IK04 IP degree of protection: IP20 conforming to IEC 60529 Climatic withstand: Conforming to IACS E10 Ambient air temperature for storage: -40â¦80 °C Fire resistance: 960 °C conforming to IEC 60695-2-11 Ambient air temperature for operation: -20â¦60 °C Mechanical robustness: Shocks: 30 Gn for 11 ms, Vibrations: 5 Gn, 5…150 Hz Operating altitude: 2000 m GV2L22 Schneider Electric is a reliable and efficient industrial circuit breaker perfect for protecting electrical circuits in various industrial applications. This high-quality item can be purchased at PLC2Day, ensuring that your electrical systems are always safe and secure.
Specification
Weight | 1,00 kg |
---|---|
Packing Quantity |
1 Unit(s) |
Unit of Measure |
Unit(s) |
Brand | |
Category |
Control and Switch Gear |
Description |
Motor circuit breaker, TeSys GV2 |
MPN |
GV2L22 |
Other Notations |
GV2L22 |
Fabr. Art. Nr. |
GV2L22 |