SCHNEIDER ELECTRIC RM35UB330
SCHNEIDER ELECTRIC RM35UB330  111,26 Excl. tax:  91,95
Back to products
SCHNEIDER ELECTRIC XBTZG935 388570
SCHNEIDER ELECTRIC XBTZG935 388570  201,47 Excl. tax:  166,50

SCHNEIDER ELECTRIC LRD22 034684

SKU: 2401300008

SCHNEIDER ELECTRIC LRD22 034684

 44,71 Excl. tax:  36,95

1 in stock

1 in stock

17 People watching this product now!

Netherlands, Europe

Today

Europe
USA
Rest of the World
1-3 Days
2-3 Days
3-6 Days
Europe
USA
Rest of the World
1-2 Days
1-2 Days
2-4 Days

Delivery:

Payment Methods:

Description

TeSys Deca, thermal overload relay, 16 to 24 A, class 10A: Specifications, Main, Range, TeSys, TeSys Deca, Product name, TeSys LRD, TeSys Deca, Product or Component Type, Differential thermal overload relay, Device short name, LRD, Relay application, Motor protection, Product Compatibility, LC1D25, LC1D32, LC1D38, Network type, DC, AC, Thermal overload class, Class 10A IEC 60947-4-1, Thermal protection adjustment range, 16…24 A, [Ui] rated insulation voltage, Power circuit 600 V CSA, Power circuit 600 V UL, Power circuit 690 V IEC 60947-4-1, Complementary, Network Frequency, 0…400 Hz, Mounting support, Plate, with specific accessories, Rail, with specific accessories, Under contactor, Tripping threshold, 1.14 +/- 0.06 Ir IEC 60947-4-1, Auxiliary contact composition, 1 NO + 1 NC, [Ith] conventional free air thermal current, 5 A signalling circuit, Permissible current, 1.5 A 240 V AC-15 signalling circuit, 0.1 A 250 V DC-13 signalling circuit, [Ue] rated operational voltage, 690 V AC 0…400 Hz power circuit IEC 60947-4-1, Associated fuse rating, 4 A gG for signalling circuit, 4 A BS for signalling circuit, [Uimp] rated impulse withstand voltage, 6 kV, Phase failure sensitivity, Tripping current 130 % of Ir on two phase, the last one at 0, Control type, Red push-button stop, Blue push-button reset, Temperature compensation, -4…140 °F (-20…60 °C), Connections – terminals, Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible without cable end, Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end, Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) solid, Power circuit screw clamp terminals 1 0.00…0.02 in² (1.5…10 mm²) flexible without cable end, Power circuit screw clamp terminals 1 0.00…0.01 in² (1…6 mm²) flexible with cable end, Power circuit screw clamp terminals 1 0.00…0.02 in² (1.5…10 mm²) solid, Tightening torque, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals, Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals, Height, 2.60 in (66 mm), Width, 1.77 in (45 mm), Depth, 2.76 in (70 mm), Net Weight, 0.27 lb(US) (0.124 kg), Environment, Climatic withstand, IACS E10, IP degree of protection, IP20 conforming to IEC 60529, Ambient air temperature for operation, -4…140 °F (-20…60 °C) without derating IEC 60947-4-1, Ambient Air Temperature for Storage, -76…158 °F (-60…70 °C), Flame retardance, V1 conforming to UL 94, Mechanical robustness, Vibrations6 Gn IEC 60068-2-6, Shocks15 Gn for 11 ms IEC 60068-2-7, Dielectric strength, 1.89 kV 50 Hz IEC 60947-1, Standards, EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, GB/T 14048.4, GB/T 14048.5, EN 50495, Product Certifications, IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS (Lloyds register of shipping), ATEX INERIS, UKCA. Specifications: Main Range: TeSys TeSys Deca Product name: TeSys LRD TeSys Deca Product or Component Type: Differential thermal overload relay TeSys Deca Device short name: LRD Relay application: Motor protection Product Compatibility: LC1D25, LC1D32, LC1D38 Network type: DC, AC Thermal overload class: Class 10A IEC 60947-4-1 Thermal protection adjustment range: 16…24 A [Ui] rated insulation voltage: Power circuit 600 V CSA, Power circuit 600 V UL, Power circuit 690 V IEC 60947-4-1 Complementary: Network Frequency: 0…400 Hz Mounting support: Plate, with specific accessories, Rail, with specific accessories, Under contactor Tripping threshold: 1.14 +/- 0.06 Ir IEC 60947-4-1 Auxiliary contact composition: 1 NO + 1 NC [Ith] conventional free air thermal current: 5 A signalling circuit Permissible current: 1.5 A 240 V AC-15 signalling circuit, 0.1 A 250 V DC-13 signalling circuit [Ue] rated operational voltage: 690 V AC 0…400 Hz power circuit IEC 60947-4-1 Associated fuse rating: 4 A gG for signalling circuit, 4 A BS for signalling circuit Environment: Climatic withstand: IACS E10 IP degree of protection: IP20 conforming to IEC 60529 Ambient air temperature for operation: -4…140 °F (-20…60 °C) without derating IEC 60947-4-1 Ambient Air Temperature for Storage: -76…158 °F (-60…70 °C) Flame retardance: V1 conforming to UL 94 Mechanical robustness: Vibrations6 Gn IEC 60068-2-6, Shocks15 Gn for 11 ms IEC 60068-2-7 Dielectric strength: 1.89 kV 50 Hz IEC 60947-1 Standards: EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, GB/T 14048.4, GB/T 14048.5, EN 50495 Product Certifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS (Lloyds register of shipping), ATEX INERIS, UKCA Schneider Electric LRD22 034684 is a reliable and high-quality industrial item. It is commonly used in various industrial applications such as motor protection. This item can be purchased at spareparts2day.

 

Specification

Weight 1,00 kg
Packing Quantity

1 Unit(s)

Unit of Measure

Unit(s)

Brand

SCHNEIDER ELECTRIC

Category

Control and Switch Gear

Description

TeSys Deca, thermal overload relay,

MPN

LRD22 034684

Other Notations

LRD22 034684

,

LRD22034684

Fabr. Art. Nr.

LRD22 034684