Non-contact safety switches: System part Sensor with actuator, Sensor principle Magnetic, Number of N/O contacts 1, Number of N/C contacts 1, Safe switch on distance Sao 5 mm, Safe switch off distance Sar 15 mm, Active sensor surfaces 2, Actuation directions 5, Safety-related parameters, B10d parameter 2 x 107, switching cycles (with small load), Type Type 4 (EN ISO 14119), Actuator coding level Low coding level (EN ISO 14119), Safe state in the event of a fault The switch has no internal fault detection and is unable to assume a safe state in the event of, a fault. Fault detection is performed by the connected safety-related logic unit., Functions, Safe series connection None, only individual wiring (with diagnostics), Interfaces, Connection type Cable, Length of cable 10 m, Cable material PVC, Electrical data, Type of output Reed contacts, Switching voltage ≤ 30 V DC, Switching current ≤ 30 mA, Mechanical data, Design Rectangular, Dimensions (W x H x D) 19 mm x 82 mm x 19 mm, Weight + 0.322 kg, 2 SAFETY SWITCHES | SICK Product data sheet | 2023-07-11 19:19:47, Subject to change without notice, RE300-DA10P | RE300, NON-CONTACT SAFETY SWITCHES, Housing material ABS shape, Ambient data, Enclosure rating IP67, Ambient operating temperature –10 °C … +55 °C, Storage temperature –25 °C … +70 °C, Vibration resistance 10 Hz … 55 Hz, 0.35 mm (IEC 60068-2-6), Shock resistance 30 g (IEC 60068-2-29)<ul> <li>Non-contact safety switches: System part Sensor with actuator</li> <li>Sensor principle Magnetic</li> <li>Number of N/O contacts 1</li> <li>Number of N/C contacts 1</li> <li>Safe switch on distance Sao 5 mm</li> <li>Safe switch off distance Sar 15 mm</li> <li>Active sensor surfaces 2</li> <li>Actuation directions 5</li> <li>Safety-related parameters B10d parameter 2 x 107, switching cycles (with small load)</li> <li>Type Type 4 (EN ISO 14119)</li> <li>Actuator coding level Low coding level (EN ISO 14119)</li> <li>Safe state in the event of a fault The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit.</li> <li>Functions Safe series connection None, only individual wiring (with diagnostics)</li> <li>Interfaces Connection type Cable</li> <li>Length of cable 10 m</li> <li>Cable material PVC</li> <li>Electrical data Type of output Reed contacts</li> <li>Switching voltage ⤠30 V DC</li> <li>Switching current ⤠30 mA</li> <li>Mechanical data Design Rectangular</li> <li>Dimensions (W x H x D) 19 mm x 82 mm x 19 mm</li> <li>Weight + 0.322 kg</li> <li>Enclosure rating IP67</li> <li>Ambient operating temperature â10 °C … +55 °C</li> <li>Storage temperature â25 °C … +70 °C</li> <li>Vibration resistance 10 Hz … 55 Hz, 0.35 mm (IEC 60068-2-6)</li> <li>Shock resistance 30 g (IEC 60068-2-29)</li> </ul><p><strong>RE300-DA10P 6025079 Sick</strong> is a high-quality industrial item available at PLC2Day. This item is widely used in various industrial applications. It offers exceptional performance and reliability, making it ideal for industries such as manufacturing, automation, and robotics. Purchase the <strong>RE300-DA10P 6025079 Sick</strong> at PLC2Day to enhance your industrial operations.</p>